DS9370 TriTech CM Ceiling Detector
Flag notes: Current draw differs across docs (28/39/24 mA) · Tamper rating 100 mA vs 125 mA within manual · Detector manual gives no EOL value; EOL comes from the panel/B208 doc
| Terminal | Group | Function | Connects to | |
|---|---|---|---|---|
| 1 (−) | Power | Aux − | Flag | |
| 2 (+) | Power | Aux + 9–15 VDC, ≥22 AWG | Flag | |
| 3 NO | Alarm | Form C NO | Flag | |
| 4 C | Alarm | Relay common | Flag | |
| 5 NC | Alarm | Relay NC (use 4 & 5 for NC loops) | Flag | |
| 6, 7 T | Tamper | NC tamper | Flag | |
| 8 M | Memory | 6–18 VDC control input | Flag |
| Power | 9–15 VDC, 28 mA max |
|---|---|
| Alarm relay | Form C, 100 mA 28 VDC 2.8 W, transfers 4 s |
| Tamper | NC, 28 VDC |
| Mount height | 8–20 ft (12 ft recommended) |
| Coverage | 360°, up to 54 ft diameter |
| Microwave | 10.525 GHz (DS9370/DS9371) |
Do not use relay with capacitive/inductive loads
No removable ceiling tiles without back plate
Wait 2 min after power-up before walk test
Masks: two 120°, two 90°
Classic Line TriTech CM Installation manual · F.01U.427.436 rev 01 (2024-09)
Values from F.01U.427.436 rev 01 (2024-09).
Verify against the manufacturer's install guide.