HireLV Handbook › Wiring diagrams › Intrusion › DMP › XR150

DMP XR150 Control Panel

Suggest a correction

Suggest a correction

A free account is required. Reports stay private until a correction is published.

XR150 Control Panel

Nc 1k eol No 1k eol 2 wire smoke Keypad bus Bell eol
DMP XR150DMP XR150 Nc 1k eol. 1, 2 connects to 16.5 VAC 50 VA (327) or 16 VAC 56/100 VA wire-in. 3 +B, 4 −B connects to 12 VDC SLA; terminal 4 to earth ground. 5 BELL, 6 GND connects to 12 VDC bell/horn, supervised (1 kΩ ½ W EOL for sirens). 7 RED connects to +12 VDC regulated aux. 8 YEL connects to Data in from keypads. 9 GRN connects to Data out to keypads. 10 BLK connects to Ground. 11, 12 connects to +12 VDC resettable / ground. 13, 15 connects to Voltage sensing; 14 = ground. 16, 18 connects to 17 = ground. 19, 21 connects to 20 = ground. 22, 24 connects to 23 = ground. 25–26, 27–28 connects to 2-wire smoke, Class B Style A. OUT1–OUT2 header connects to Two 305 SPDT relays via 431 harness, 1 A @ 30 VDC.DMP XR150Nc 1k eolAC1, 216.5 VAC 50 VA (327) or 16 VA…Battery3 +B, 4 −B12 VDC SLA; terminal 4 to ear…Bell5 BELL, 6 GND12 VDC bell/horn, supervised…Keypad bus7 RED+12 VDC regulated aux8 YELData in from keypads9 GRNData out to keypads10 BLKGroundSmoke power11, 12+12 VDC resettable / groundZones 1, 213, 15Voltage sensing; 14 = groundZones 3, 416, 1817 = groundZones 5, 619, 2120 = groundZones 7, 822, 2423 = groundZones 9, 1025–26, 27–282-wire smoke, Class B Style ARelaysOUT1–OUT2 headerTwo 305 SPDT relays via 431 h…
DMP XR150 Nc 1k eol. 1, 2 connects to 16.5 VAC 50 VA (327) or 16 VAC 56/100 VA wire-in. 3 +B, 4 −B connects to 12 VDC SLA; terminal 4 to earth ground. 5 BELL, 6 GND connects to 12 VDC bell/horn, supervised (1 kΩ ½ W EOL for sirens). 7 RED connects to +12 VDC regulated aux. 8 YEL connects to Data in from keypads. 9 GRN connects to Data out to keypads. 10 BLK connects to Ground. 11, 12 connects to +12 VDC resettable / ground. 13, 15 connects to Voltage sensing; 14 = ground. 16, 18 connects to 17 = ground. 19, 21 connects to 20 = ground. 22, 24 connects to 23 = ground. 25–26, 27–28 connects to 2-wire smoke, Class B Style A. OUT1–OUT2 header connects to Two 305 SPDT relays via 431 harness, 1 A @ 30 VDC.

Terminals Flag

TerminalGroupFunctionConnects to
1, 2 AC 16.5 VAC 50 VA (327) or 16 VAC 56/100 VA wire-in Flag
3 +B, 4 −B Battery 12 VDC SLA; terminal 4 to earth ground Flag
5 BELL, 6 GND Bell 12 VDC bell/horn, supervised (1 kΩ ½ W EOL for sirens) Flag
7 RED Keypad bus +12 VDC regulated aux Flag
8 YEL Keypad bus Data in from keypads Flag
9 GRN Keypad bus Data out to keypads Flag
10 BLK Keypad bus Ground Flag
11, 12 Smoke power +12 VDC resettable / ground Flag
13, 15 Zones 1, 2 Voltage sensing; 14 = ground Flag
16, 18 Zones 3, 4 17 = ground Flag
19, 21 Zones 5, 6 20 = ground Flag
22, 24 Zones 7, 8 23 = ground Flag
25–26, 27–28 Zones 9, 10 2-wire smoke, Class B Style A Flag
OUT1–OUT2 header Relays Two 305 SPDT relays via 431 harness, 1 A @ 30 VDC Flag

Key specs

Aux12 VDC 1.5 A max
Total2 A (50VA jumper) or 3 A (75VA jumper)
EolDMP 311 1 kΩ
Zone thresholdsopen >1300 Ω, normal 600–1300 Ω, short <600 Ω
Response500 ms (160 ms fast, zones 1–10)
KeypadsXR150: 8 supervised; 16 bus devices
Smoke zones3000 ft 18 AWG / 1000 ft 22 AWG, 100 Ω max

Ground the panel before applying power

Do not use shielded wire on LX-Bus/keypad bus

Transformer ≤70 ft 16 ga or 40 ft 18 ga

How to wire it

  1. Connect 1, 2 to 16.5 VAC 50 VA (327) or 16 VAC 56/100 VA wire-in.
  2. Connect 3 +B, 4 −B to 12 VDC SLA; terminal 4 to earth ground.
  3. Connect 5 BELL, 6 GND to 12 VDC bell/horn, supervised (1 kΩ ½ W EOL for sirens).
  4. Connect 7 RED to +12 VDC regulated aux.
  5. Connect 8 YEL to Data in from keypads.
  6. Connect 9 GRN to Data out to keypads.
  7. Connect 10 BLK to Ground.
  8. Connect 11, 12 to +12 VDC resettable / ground.
  9. Connect 13, 15 to Voltage sensing; 14 = ground.
  10. Connect 16, 18 to 17 = ground.
  11. Connect 19, 21 to 20 = ground.
  12. Connect 22, 24 to 23 = ground.
  13. Connect 25–26, 27–28 to 2-wire smoke, Class B Style A.
  14. Connect OUT1–OUT2 header to Two 305 SPDT relays via 431 harness, 1 A @ 30 VDC.

Source

XR150/XR550 Series Installation Guide · LT-1233 rev 25122 (© 2024–2025)

Values from LT-1233 rev 25122 (© 2024–2025).

Verify against the manufacturer's install guide.

Open in builder

Related parts

Planning aid only. Values are typical and vary by manufacturer, code edition and jurisdiction. Verify with manufacturer data, NEC/NFPA/TIA and the local AHJ. HireLV is not liable for designs based on these tools.