HES 1006 Electric Strike
Suggest a correction
1006 Electric Strike
HES 1006 HES 1006 12 VDC plug. 12 VDC plug pigtail connects to Use for 12 VDC; black pigtail wire = negative. 24 VDC plug pigtail connects to Use for 24 VDC; black pigtail wire = negative. Black + Violet connects to 12 V: join to +12 VDC. Red + Red/green connects to 12 V: join to − NEG. Violet connects to 24 V: + 24 VDC. Black + Red/green connects to 24 V: join together only (not to supply). Red connects to 24 V: − NEG. White / Orange / Green connects to Latchbolt monitor C / NO / NC. Brown / Blue / Yellow connects to Latchbolt strike monitor C / NO / NC. HES 1006 12 VDC plug Power 12 VDC plug pigtail Use for 12 VDC; black pigtail… 24 VDC plug pigtail Use for 24 VDC; black pigtail… Solenoid (no connector) Black + Violet 12 V: join to +12 VDC Red + Red/green 12 V: join to − NEG Violet 24 V: + 24 VDC Black + Red/green 24 V: join together only (not… Red 24 V: − NEG LBM option White / Orange / Green Latchbolt monitor C / NO / NC LBSM option Brown / Blue / Yellow Latchbolt strike monitor C /…
HES 1006 12 VDC plug. 12 VDC plug pigtail connects to Use for 12 VDC; black pigtail wire = negative. 24 VDC plug pigtail connects to Use for 24 VDC; black pigtail wire = negative. Black + Violet connects to 12 V: join to +12 VDC. Red + Red/green connects to 12 V: join to − NEG. Violet connects to 24 V: + 24 VDC. Black + Red/green connects to 24 V: join together only (not to supply). Red connects to 24 V: − NEG. White / Orange / Green connects to Latchbolt monitor C / NO / NC. Brown / Blue / Yellow connects to Latchbolt strike monitor C / NO / NC.
Terminals Flag
Terminal Group Function Connects to
12 VDC plug pigtail
Power
Use for 12 VDC; black pigtail wire = negative
Flag
24 VDC plug pigtail
Power
Use for 24 VDC; black pigtail wire = negative
Flag
Black + Violet
Solenoid (no connector)
12 V: join to +12 VDC
Flag
Red + Red/green
Solenoid (no connector)
12 V: join to − NEG
Flag
Violet
Solenoid (no connector)
24 V: + 24 VDC
Flag
Black + Red/green
Solenoid (no connector)
24 V: join together only (not to supply)
Flag
Red
Solenoid (no connector)
24 V: − NEG
Flag
White / Orange / Green
LBM option
Latchbolt monitor C / NO / NC
Flag
Brown / Blue / Yellow
LBSM option
Latchbolt strike monitor C / NO / NC
Flag
Key specs
Current .48 A @12 VDC, .24 A @24 VDC continuous
Resistance 25 Ω @12 V, 100 Ω @24 V
Tolerance ±10%
Wire gauge 12 V: 18 ga ≤200 ft, 16 ga 200–300 ft, 14 ga 300–400 ft; 24 V: 18 ga ≤300 ft, 16 ga 300–400 ft (round trip)
Monitor rating 500 mA @ 30 VDC
Lead colours/joins differ from the HES 9600 family; do not reuse 9600 wiring
Switch states listed for strike keeper closed and LBM unactuated (door open)
Verify supply with a meter; >10% over rating can damage solenoid
How to wire it
Connect 12 VDC plug pigtail to Use for 12 VDC; black pigtail wire = negative. Connect 24 VDC plug pigtail to Use for 24 VDC; black pigtail wire = negative. Connect Black + Violet to 12 V: join to +12 VDC. Connect Red + Red/green to 12 V: join to − NEG. Connect Violet to 24 V: + 24 VDC. Connect Black + Red/green to 24 V: join together only (not to supply). Connect Red to 24 V: − NEG. Connect White / Orange / Green to Latchbolt monitor C / NO / NC. Connect Brown / Blue / Yellow to Latchbolt strike monitor C / NO / NC.
Source
HES 1006 Series Electric Strike Installation Instructions
· AADSS1009170
rev © 2025 (PDF Mar 2025)
Values from AADSS1009170 rev © 2025 (PDF Mar 2025).
Verify against the manufacturer's install guide.
Open in builder
Save
Download SVG
Export PDF
Related parts
Planning aid only. Values are typical and vary by manufacturer, code edition and jurisdiction. Verify with manufacturer data, NEC/NFPA/TIA and the local AHJ. HireLV is not liable for designs based on these tools.